61200780L1-1C © 2004 ADTRAN, Inc. 83
ATLAS 800 Series System Manual System Config Menu Descriptions
Primary Timing Source
5. SYSTEM CONFIG MENU DESCRIPTIONS
The SYSTEM CONFIG menu allows you to set up the ATLAS operational configuration. Figure 5 shows the
items included in this menu. Menu options follow.
Figure 5. System Config Menu
Primary Timing Source
Write security: 1; Read security: 5
Selects the primary timing source. You can select either Internal or any port available that is capable of
providing timing. Please refer to the specific module information to determine whether a port can provide
timing for the system.
Backup Timing Source
Write security: 1; Read security: 5
Selects the secondary timing source. You can select either Internal or any port available that is capable of
providing timing. Please refer to the specific module information to determine whether a port can provide
timing for the system. ATLAS 800 Series uses the backup timing source if the primary timing source goes
into alarm. The backup timing source should be different from the primary timing source for the most
reliable operation.
ADLP Address
Write security: 2; Read security: 5
Shows the system ADTRAN Data Link Layer Protocol (ADLP) address for connecting remote devices to
ADTRAN management software. The allowable range is between 2 and 65520. Enter a value not used by
any other ADTRAN units controlled by the management software.
Session Timeout
Write security: 3; Read security: 5
Defines the number of seconds the terminal session must remain idle before the session times out (valid
range 0 to 65535). You can enter zero to deactivate this option (the session will never time out).