61200780L1-1C © 2004 ADTRAN, Inc. 297
ATLAS 800 Series System Manual Dial Plan
V35Nx: User Term - Ifce Config
Outgoing Caller ID Defines the number to use to provide Caller ID to the network for outgoing calls
sent through this endpoint. Choose from
SEND AS PROVIDED, SUBSTITUTE IF NOT
PRESENT, or SUBSTITUTE ALWAYS.
The Caller ID number must be specific (i.e., no wildcards).
Source ID Simplifies the creation of a dial plan in applications where the criterion for
switching calls to a certain endpoint is a function of which endpoint originated
the call.
DEFAULT VALUE = 0. Zero is the default ID for all endpoints and all accept
numbers. With default values, all calls are routed based only on the dialed
number.
Multiple endpoints can have the same
SOURCE ID.
When creating the
CALL ACCEPT list, specify a SOURCE ID(s) as well as a
dialed number or range of dialed numbers to accept.
For example, an application requires that all calls that originate from Port 1 of
the ATLAS 800 Series in Slot 1 be switched to Port 2 of that same module.
Assign a unique
SOURCE ID (e.g., 7) to Port 1 of the module, and then configure
Port 2 to only accept calls from that unique
SOURCE ID (7).
Swap ANI/DNIS Swaps the ANI and DNIS numbers received from the network. ANI (Automatic
Number Identification) is the billing number of the calling party, and DNIS
(Dialed Number Identification Service) is the called party number.
With this swap, the ATLAS 800 Series switchboard uses ANI to route the call. The
accept number in the dial plan must use the ANI number, not the DNIS number.
B Channel Selection Determines how the ATLAS 800 Series switchboard uses B channels for call
routing. The Circular method can be used for call load balancing among the
available B channels on this interface
.
V35Nx: User Term - IFCE CONFIG
Write security: 3; Read security: 5
This menu allows the user to define option parameters for ports configured for V.35 connections. Specifies
the configuration parameters for the endpoint.
Submenu Description
Normal
Always start with the last channel configured (i.e., for a full PRI channel 23
would be used if available).
Circular
Contiguous channels from last to first.