Compatible Systems Octal V.35 - 10/100 RIOP Instruction Manual Page 45

  • Download
  • Add to my manuals
  • Print
  • Page
    / 381
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 44
61200780L1-1C © 2004 ADTRAN, Inc. 45
ATLAS 800 Series System Manual Option Module Pinouts
Engineering Guidelines
T3 Drop and Insert Option Module
Using the provided RG-59, 75-Ohm cables (P/N 3125I054), each T3 Drop and Insert Option Module
(P/N 1200225L1) provides BNC connectors for primary and secondary transmit and receive connections
(see Pinout 25
).
Dual Video Option Module
The Dual Video Option Module (P/N 4200773Lx) provides a standard RS-366 dialing interface (DB-25)
and a DTE interface (provided through adapter cables). Pinout 26 shows the RS-366 dialing interface and
Pinouts 27 through 29 on the following pages show pinouts for the other available interfaces.
Pinout 25. T3 Drop and Insert Module (BNC pair, female)
Name Description
Primary RX IN Primary receive data from the network, 75 ohms ± 5%, unbalanced
Primary TX OUT Primary transmit data to the network, 75 ohms ± 5%, unbalanced
Secondary RX IN Secondary receive data from the network, 75 ohms ± 5%, unbalanced
Secondary TX OUT Secondary transmit data to the network, 75 ohms ± 5%, unbalanced
Pinout 26. Dual Video Module (RS-366, DB-25)
Pin Name Description Pin Name Description
1 Shield Shielded Ground Connection 14 NB1 Digit Signal Circuit 1
2 DPR Digit Present 15 NB2 Digit Signal Circuit 2
3 ACR Abandon Call and Retry 16 NB4 Digit Signal Circuit 4
4 CRQ Call Request 17 NB8 Digit Signal Circuit 8
5 PND Present Next Digit 18 RC Receive Common
6 PWI Power Indication 19 SC Send Common
7 SG Signal Ground 20-21 Unused n/a
8-12 Unused n/a 22 DLO Data Link Occupied
13 DSC Distant Station Connection 23-25 Unused n/a
Page view 44
1 2 ... 40 41 42 43 44 45 46 47 48 49 50 ... 380 381

Comments to this Manuals

No comments