61200780L1-1C © 2004 ADTRAN, Inc. 144
ATLAS 800 Series System Manual T3 Option Module
DS1 Alarm Status
Remote LB Write security: 3; Read security: 5
This field indicates if loopbacks initiated from remote sources are in effect and
may be used to execute remote loopbacks on the far-end T3 equipment. The
following options are available:
Remote Status Write security: 3; Read security: 5
This field indicates the progress of remote loopbacks. The following options
will display:
DS1 Alarm Status
Write security: 3; Read security: 5
Indicates T1 alarm status.
Prt Read security: 5
Indicates the number of the T1 circuit (1-28).
Alarms Read security: 5
Displays the alarm status for each of the 28 T1 circuits. An asterisk (*) indicates
the presence of an alarm and a dash (-) indicates no alarm. The following alarms
are monitored:
Options Description
None
No remote loopbacks are activated
DS3 Line
T3 line loopback active
DS1 #1... DS1 #28
Remote individual T1 line loopback is activated
DS1 All Line
Remote T1 line loopbacks for all 28 T1s is activated
Options Description
Line Loopback Active
Remote line loopback is active.
No Loops Active
Remote line loopbacks are inactive.
Alarms Description
Red
Loss of Frame or Red Alarm. Received T1 cannot be frame-synchronized. A
Red Alarm is indicated when the T1 has been out of frame for 2.5 seconds.