61200780L1-1C © 2004 ADTRAN, Inc. 351
ATLAS 800 Series System Manual
Connect to the ATLAS
1. If you are not already connected to the unit’s ADMIN or CRAFT interfaces (either with a VT100
compatible terminal or with a PC running VT100 emulation software), use the procedure in DLP-1,
Connecting the Terminal or PC to the ADMIN or CRAFT Port to connect to the
ADMIN or CRAFT
interface.
Alternatively, if the unit is part of a management cluster connected to the local network, you may use a
PC connected to the network to Telnet into the unit. Use the procedures in DLP-4, Verifying
Communications Over an IP LAN to connect to the
10/100 BASET interface.
2. Logon to the unit using the read-write password (see DLP-2, System Login and Menu Access, on
page 319 for details).
Configure the Alarm Relay
1. Go to the SYSTEM CONFIG menu and press the right arrow key to access the right-pane menus.
2. Select the A
LARM RELAY THRESHOLD menu and choose the appropriate threshold level.
The A
LARM RELAY will set for this threshold and all other alarms of greater importance. Refer to the
section called System Event Log in this system manual for a listing of all alarms and levels of
importance.
Clearing the Alarm Relay Remotely
1. Go to the SYSTEM CONFIG menu and press the right arrow key to access the right-pane menus.
2. Select the A
LARM RELAY RESET field and press <Enter>.
Setting the threshold to Normal will not set the Alarm Relay for Normal events. No Normal
events will set the Alarm Relay.
Locally clear the ALARM RELAY by pressing the ACO switch.